Add to Cart
Reliable Single Phase Meter , High Accuracy Smart KWH Meter For AMR / AMI System
Technical Features:
Specification:
Connection Mode | Accuracy | Rated Voltage V | Rated Current A | Pulse Constant |
Direct | 1.0/2.0 | 220 | 20 | 3200 |
220 | 30 | 2400 | ||
220 | 40 | 1600 | ||
220 | 50 | 1600 | ||
220 | 60 | 1200 | ||
220 | 80 | 800 | ||
220 | 100 | 800 | ||
220 | 120 | 600 | ||
Through Mutual Inductor | 1.0/2.0 | 220 | 6 | 12000 |
Remarks: Special pulse constant can be customized as inquire.
Main Parameters:
Consumption: Voltage Circuit Consumption(Out of Communication Status) ≤1.5W, 10VA
Voltage Circuit Consumption(Under Communication Status) ≤3.0W, 12VA
Current Circuit Consumption ≤1VA(Ib)
Working Temperature: -25℃~60℃
Maximum Working Temperature: : -40℃~70℃
Maximum Storage and Transportation Temperature: -40℃~70℃
Relative Humidity: Annual Average<75%
Normal Working Pressure: 0.9Un~1.1Un
External Working Pressure: 0.8Un~1.15Un
Maximum Working Pressure: 0.0Un~1.15Un
Clock Accuracy: ≤0.5S/D (Reference Temperature 23℃)
Capacity of Li-Ion Battery: ≥1.2Ah, the working time since power off≥ 5 years.
Data Storage Period ≥ 10 years
Life Time ≥ 10 years
Dimension: 112*160*71 mm
Weight: 0.8kg
Pulse Width: 80±20mS, Typical 80mS
Communication Rate for Optical: 1200bps
Communication Rate for RS485: 2400bps (Typical Value)
600bps, 1200bps, 2400bps, 4800bps, 9600bps (Can be set)
Safety precautions:
* Use only isolated tools.
* Do not connect the meter to a 3 phase - 415V AC - network.
* Place the meter only in dry surroundings.
* Make sure the used wires are suitable for the max current the meter can measure.
* Make sure the AC wires are installed correctly before activating the current/voltage.
* Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
* Do not through, drop, kick or other physical violence to the meter as there are high precision components inside that will break or make the meter measure inaccurate.
* Do not mount the meter in area's with harm gas, dust, mildew or insects or on unstable surfaces.