This range of water meter is used to measure the total quantity of cold(hot) potable water which consumed in household or a resident unit, passing through the pipeline.
Compliance with standard: ISO 4064 Class B
Feature
• Dry-dial, magnetic drive, Resistance to exterior magnet interference
• Multi-jet
• Selected high quality materials for steady&reliable characteristic
• Vacuum sealed register ensures the dial kept free from fog and keep the reading clear in a long term service
• Measuring accuracy conform to ISO 4064 class B Standard
• universal Use. Easy For Interchange&maintenance
• Cold water meter or hot water meter for option
MAIN TECHNICAL DATA
Meter size Dia DN (mm) |
Class | Qs Overload Flow | Qp Nominal Flow | Qt Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
m3/h | 1/h | m3 | |||||
15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
B | 120 | 30 | |||||
20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
B | 200 | 50 | |||||
25 | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
B | 280 | 70 | |||||
32 | A | 12 | 6.0 | 600 | 240 | 0.0001 | 99999 |
B | 480 | 120 | |||||
40 | A | 20 | 10 | 1000 | 400 | 0.001 | 99999 |
B | 800 | 200 | |||||
50 | A | 30 | 15 | 4500 | 1200 | 0.001 | 99999 |
B | 3000 |
450 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate(qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) |
L length |
B Width |
H Height |
Connecting Thread D |
Weight kg |
mm | |||||
15 | 165 | 99 | 104 | G3/4"B | 1.5 |
20 | 190 | 99 | 106 | G1"B | 1.7 |
25 | 225 | 104 | 120 | G11/4"B | 2.4 |
32 | 230 | 104 | 120 | G11/2"B | 2.7 |
40 | 245 | 125 | 155 | G2"B | 4.5 |
50 | 300 | 125 | 155 | G21/2"B | 7.2 |
280 | 165 | 175 | GB4216.4 D=165 D1=125 Flange connecting conform to GB4216.4 D=165 D1=125 |
14 |