Add to Cart
RS485 Three Phase Electric Meters 3P3W Energy Meter Multi Tariff Active Energy Measure
The 3P meter integrates high precision metrology with diversity of wireless communication technology completed in a plug & play module unit, allowing it to be utilized as element of AMR AMI solution. It operates in three phase four wire and three wire network. And it is with anti-tamper functions and completed in a BS 5685 footprint case. The meter is mainly used for commercial and inustrial environments.
The meter works with a modular design of wireless communication. A utility and service provider can select from various communication modules to setup their AMR AMI facilities. The module unit is replaceable and easy to repair.
Featured functions
■Active and reactive energy measurement in both directions
■ Load profiling and Maximum demand recording at programmable intervals
■Flexible swap between credit and prepayment mode
■ Full spectrum of metrological measurement of V, A, P, PF, etc.
■Available for both direct and CT/VT connection
■Available for both four wires and three wires network
■Adjustable power limit
■Optical and RS485 com port
User benefits
1) All-in-one instrumentation
2) Low operational and deployment cost
3) Allows for multi-rate and usage register on TOU basis
4) Setting for tariff, emergency unit, load limit, surchages, debt collection, etc.
5) Anti-tamper: earthing, cover open, bypass, etc
6) Broad metrological range to reduce inventory cost
Specifications:
Electrical parameters |
|
---|---|
Nominal voltage Un |
3x 220/230/ 240V |
Limited voltage |
60%~120%Un |
Frequency |
50/60Hz+5% |
Basic current(Ib) |
5A |
Maximum current(Imax) |
100A |
Starting current(Ist) |
30mA |
Active energy constant |
400imp/kWh |
Accuracy |
|
Active energy to IEC62053‐21 |
Class1.0 |
Reactive energy to IEC62053‐23 |
Class2.0 |
Power Consumption |
|
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Temperature range |
|
Operation meter |
25℃ to+70℃ |
Storage |
40℃ to+85℃ |
|
|
Insulation strength |
|
AC Insulation strength |
4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections |
8kV |
|
|
Electro Magnetic Compatibility |
|
Electrostatic discharges |
|
Contact discharge |
8kV |
Air discharge |
16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical |
10V/m |
100kHz to 1GHz typical |
30V/m |
Fast transient burst test |
4kV |
Mechanical requirements |
|
Protection Rating |
IP54 |
Insulation Classification |
Protective Class II |
Maximum cable size |
10 mm |