WUHAN RADARKING ELECTRONICS CORP.

WUHAN RADARKING ELECTRONICS CORP. Electric Meter, Smart Water Meter, Smart Gas Meter & AMI solution

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Single Phase Electric Meter /

Smart Single Phase Electric Meter Active Energy Measuring ANSI Kwh Meter

Smart Single Phase Electric Meter Active Energy Measuring ANSI Kwh Meter

Ask Latest Price
Brand Name :Radarking
Model Number :ANSI 1S
Certification :IEC62053-21; IEC62052-11; ANSI
Place of Origin :Made in China
MOQ :500pcs
Price :Negotiation
Payment Terms :L/C, T/T, Western Union
Supply Ability :6000000 pcs/year
Delivery Time :20-40 working days
Packaging Details :Standard Packing in Carton
Product Name :ANSI Single Phase Static Electric Meter
Output Voltage :120/240V
Output Current :200A
Display :LCD
Communication :PLC or RF
Frequency :50 / 60Hz
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Professional Smart Single Phase Electric Meter Active Energy Measuring ANSI Meter

Description:
The Wuhan Radarking has the most advanced single phase electronic watt hour meter that uses large integrated circuits. It uses digital sampling and SMT technique which is suitable for measuring active energy in electric net with single phase Alternating Current 50Hz or 60Hz. A Liquid Crystal Display(LCD) is used for the register. Then meter must be mounted on a location with temperature range of -25C to +55C and relative humidity not exceeding 95%. The air should be free of harmful gases, dust, mildew, insect, etc.

Specifications:

Operating Volt
Operating Freq.
240V/120V, +20%~-50%
60/50Hz, 46-64 Hz line frequency range with same calibration
Operating EnvironmentTemperature: -30°to +75ºC
Humidity: 0% to 95% non-condensing
AccuracyExceeds IEC62053 / ANSI C12.20 standards
Energy Display

LCD Display

Six-digit, Digit Height: 0.52", 6x1 or 5x2

Cyclometer

Five-digit, Digit Height: 0.5", 5x1 or 4x2

Starting Watts5 Watts
Burden Data
(for FM2S 240V Meter)
Voltage Circuit:
Voltage: 240
Watts: <0.8
VA: < 5
Current Coil-Self Contained TA: 60Hz
Service: 3-Wire TA: 30 VA: < 0.50
Working Life> 15 years (battery > 10 years)


Function:
1) Measurements

* Energy (kWh) and Active Power (kW)
* Delivered only
* Received only
* Delivered + Received
* Delivered - Received
* Energy (kvarh) in two ways: Delivered and Received (LCD only)
* Instantaneous values: voltage, current, frequency, temperature etc (LCD only)

2) LCD Display
* Display of Energy configurable to 4, 5 or 6 digits
* Energy and instantaneous power are displayed on LCD
* Three display modes:
* Normal, display energy and instantaneous power
* Alternate, display all measurement items
* Frozen, display error and caution inner meter

3) AMR (optional)
* Two UART port:
* One is used to work with 3rd party suppliers of communication systems to integrate AMR technology
* The other is optical port, local read by handset
* Compliant ANSI C12.18 and ANSI C12.19.
* MeterBuddy software
* Read the state information and data from meter.
* Set or change sag and thresholds.
* Perform a master reset to clear energy values; voltage event and power fail record.
* Obtain a meter program and data summary report.

4) Load Control (optional)
* Remote connect and disconnect
* Auto disconnect logic
* Supply capacity limit
* Emergency Supply capacity limit
* Active power limit

Features & Benefits:
1) High reliability
2) Low starting watts
3) Low burden
4) Anti-tamper design
The LIBRA-1 meters' anti-tamper features include measuring energy even if the meter is inverted and detecting when the meter is removed from a live socket.
5) Large easy to read LCD display (or Cyclometer optional)
6) Nocturnal visibility
When the environment low light, the LCD backlight automatically open.

7) Battery (optional)
Offers a cover battery port enabling changing of the meter battery without removing the meter inner-cover.

8) Remote Disconnect (optional, 200A max)
9) Network Applications
Ready for an automatic meter reading (AMR) system. Several options are available for network communication technologies, various PLC and RF modules.

10) Four options for Energy Accumulation
Delivered only, Delivered + Received, Delivered - Received, Received only

11) Functionality modularized architecture
Allows new snap-in specific modules to be installed into the meter without disturbing the finely calibrated measurement function. Optional snap-in modules include demand, time-of-use (TOU), load profile and various communication protocol options.

12) ANSI standards compatible
* ANSI C12.1-1995 ANSI C12.10-1997
* ANSI C12.18-1996 ANSI C12.19-1997
* ANSI C12.20(Class 0.5)-1998 ANSI C37.90.1-1989
* ANSI C62.45-1992 IEC 61000-4-4
* IEC 61000-4-2 FCC Part 15,Subclass C


About Us:
The Wuhan Radarking has the most advanced single phase electronic watt hour meter that uses large integrated circuits. It uses digital sampling and SMT technique which is suitable for measuring active energy in electric net with single phase Alternating Current 50Hz or 60Hz. A Liquid Crystal Display(LCD) is used for the register. Then meter must be mounted on a location with temperature range of -25C to +55C and relative humidity not exceeding 95%. The air should be free of harmful gases, dust, mildew, insect, etc.

Diagram:

Smart Single Phase Electric Meter Active Energy Measuring ANSI Kwh Meter











































































China Smart Single Phase Electric Meter Active Energy Measuring ANSI Kwh Meter for sale

Smart Single Phase Electric Meter Active Energy Measuring ANSI Kwh Meter

Inquiry Cart 0